Chapter 3 Changing the Library Configuration
Changing the Emulation Setting
Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide 59
Changing the Emulation Setting 3
The Emulation option allows you to set the library to act as either a
Quantum ATL library or an M4 Data library.
To set the emulation:
1Access the Configuration screen (see Accessing the
Configuration Screen on page53).
2Press the Up or Down buttons until Emulation is highlighted.
3Press Select.
4Use the Up or Down buttons to select the desired Emulation
setting. The available settings are ATL M2500, ATL 1500, and
M4 Data.
5Press Select.
To return to the Configuration screen without changing the
option setting, press Cancel.
6Press Main to return to the main screen.
Note: The default setting for the L25 is M4 Data; the default
setting for the L100 is ATL M2500.
Caution: If you do not return to the main screen after
changing this setting, your change will not be
saved to NVRAM.
Note: You must reboot the library before this setting will
take effect.