Chapter 3 Changing the Library Configuration
Changing the Baud Rate Setting
Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide 67
Changing the Baud Rate Setting 3
The Baud Rate option controls the baud rate setting of the serial
diagnostics port. You can set the baud rate to any standard rate
between 1200 baud and 38400 baud.
To set the Baud Rate:
1Access the Configuration screen (see Accessing the
Configuration Screen on page53).
2Press the Up or Down buttons until Baud Rate is highlighted.
3Press Select.
4Use the Up or Down buttons to select the desired Baud Rate
setting. The available settings are 38400, 19200, 9600, 4800,
2400, and 1200.
5Press Select.
To return to the Configuration screen without changing the
option setting, press Cancel.
6Press Main to return to the main screen.
Setting the Time 3
To set the time:
1Access the Configuration screen (see Accessing the
Configuration Screen on page53).
2Press the Up or Down buttons until Time is highlighted.
3Press Select.
Caution: If you do not return to the main screen after
changing this setting, your change will not be
saved to NVRAM.