802BT/802R Video Test Generator User Guide 7
Outputs Key
The Outputs key turns all signal outputs on or off when the generator is in normal
operating mode. This is the master output signal control. When the master output control
is turned off, all of the signal outputs (video and sync) of the generator are disabled.
LCD
The generator displays format and image information on the LCD in either of these modes:
Default display mode: This mode displays an index sequence number left of the
current format and current image. The image version number, which appears on the
display,represents a version of a image that has multiple versions associated with it.
Status Display mode: This mode replaces the index numbers with codes, which
provide additional information about the active format. This mode is useful when
working with multiple video signal outputs and color encoding methods.
Video types:
A for analog video
D for DVI video
H for HDMI video
Color depths:
4 for 4-bits per pixel depth
8 for 8-bits per pixel depth
Color space:
Key Function Command
ON Toggles on and off all video and sync.
OUTG

H32 150=DMT0660

V60 250=SMPTE133

Format index Format name
Image name
Image index
Horizontal rate
Vertical rate
H31 D8C=DMT0659
V60 0=SMPTE133
Video type Format name
Image name
Color depth
Color space
Image version