Video Test Generator User Guide 553
Class System parameter settings
Description Sets up the text string that is placed in the upper portions of the SMPTE133 and Cubes
images. The command can be used to add a company name or other identification to the
images. The command will not change the text in a currently displayed image; it must be
redrawn to use the new text. The factory default string is “Quantum Data.” The UIDN?
query returns the current text string.
Command syntax UIDN string
string
text string 80 characters in length
Query syntax UIDN?
Query response string
Other required
commands The IMGU command redraws the last selected test image. The ALLU command updates
hardware to the new setting and redraws the test image.
Example
UIDN "XYZ Monitor Mfg." // Change text string
IMGL SMPTE133 // Select image that uses the text string
IMGU // Draw the image using new string