246 Appendix A Command Reference
BALG dc BALancing Gate
Class Format parameter setting - Digital video signal
Description Enables and disables adding DC balancing to the Open LVDI digital outputs on generators
that support LVDI outputs. FPD-Link compatible displays use unbalanced (BALG 0), while
OpenLDI displays use balanced (BALG 1).
The BALG? query returns the current setting of BALG.
Command syntax BALG mode
mode
0 = OFF
1 = ON
Query syntax BALG?
Query response
mode
Other required
commands FMTU or ALLU