718 Appendix C Error Messages
2400 Analog composite sync type and digital separate sync type incompatible
The generator hardware configuration does not support analog composite sync and digital
separate sync being active at he same time for the given analog composite sync type
parameter value (ASCT setting) and digital separate sync type parameter value (DSST
setting).
2401 Invalid horizontal sync pulse delay
The generator hardware configuration does not support the format’s current horizontal
sync pulse delay setting
2405 Frame sync pulse delay negative
The video format’s frame sync pulse delay setting must be zero or a positive number.
2406 Frame sync pulse delay too large
The video format’s frame sync pulse delay setting exceeds the maximum limit supported
by the generator hardware configuration.
2407 Negative probe sync pulse vertical delay
The video format’s probe pulse vertical delay setting must be zero or a positive number.
2408 Probe sync pulse vertical delay too large
The video format’s probe pulse vertical delay setting exceeds the maximum limit
supported by the generator hardware configuration.
2409 Negative probe sync pulse horizontal delay
The video format’s probe pulse horizontal delay setting must be zero or a positive number.
2410 Probe sync pulse horizontal delay too large
The video format’s probe pulse horizontal delay setting exceeds the maximum limit
supported by the generator hardware configuration.
2425 Sync type selection not supported
The current firmware does not support the video format’s active sync type selection (SSST
setting) or the active sync type selection is not supported by the current analog video type
selection (AVST setting).
2430 Vertical pulse delay extends sync beyond blanking
The generator hardware configuration does not support non-interlaced video formats
having a vertical sync pulse period greater that the vertical blanking period
2450 Vertical pulse delay extends sync beyond blanking
The generator hardware configuration does not support interlaced video formats having a
vertical sync pulse period greater that the individual blanking periods between the fields.