Video Test Generator User Guide 493
PUTR PUT Relative
Class Direct processor control
Description Writes the specified value value into the location pointed to by the address register (see
the ADDR command). The parameter value is interpreted according to the current setting
of BASE (see the BASE command). The number and format of the bits written depend on
the current setting of SIZE (see the SIZE command). The address register is automatically
incremented by SIZE bits after the current location has been written to.
Note: This command is used only with custom applications and command files created by
Quantum Data. Indiscriminate use of this command can cause the generator to stop
operating and the loss of stored data in non-volatile RAM.
Command syntax PUTR value
value
0 to (2^(SIZE))-1
Other required
commands PUTR expects parameters formatted according to the current radix set by the BASE
command.