802BT/802R Video Test Generator User Guide 19
Summary of special modes

The following table describes the special operating modes, and how to configure the

modes using the physical controls or the command line interface.

Special mode Function Physical control Command
Initialize with factory
defaults Re-initializes generator to fac-
tory defaults. Removes all spe-
cial modes, deletes all custom
objects.
ACS, DSS

INIT

Calibrate Calibrates the generator. R, G, B

SCAL

SROP 32

Clone Copies configuration settings
from one generator to other
generators using a PCMCIA
card.
Step, Outputs Set: SROP 64
Rst: SROP 0 64
Old format library Displays old format names on
LCD.
G Set: SROP 1
Rst: SROP 0 1
Remove all modes Removes all special modes. ACS, DCS, DSS Set: SROP 0
Set GPIB address Sets the GPIB address. DCS Set: GPIB

addr

Rst: INIT
Set baud rate to 9600 Sets baud rate of RS-232 port
to 9600 bps.
R, DCS Set: SROP 256
Rst: SROP 0 256
Enable programmable
keypad
R, OUTPUT Set: SROP 512
Rst: SROP 0 512
Enable numeric key-
pad
Enables remote operation
through remote keypad.
R Set: SROP 128
Rst: SROP 0 128
Analog friendly mode C auses all digital formats to
output analog video signal.
R, B Set: SROP 4
Rst: SROP 0 4
Enable status display Provides additional information
on LCD (analog/digital and
color depth).
Step, G, B Set: SROP 8
Rst: SROP 0 8
DCS priority scheme Changes priority scheme for
putting CS on separate VS and
HS sync outputs when any dig-
ital composite sync (DCS) type
is selected
Step, DCS Set: SROP 4096
Rst: SROP 0 4096
Digital friendly mode Causes all analog formats out-
put digital signal
G, B Set: SROP 2
Rst: SROP 0 2
Color difference
friendly
Outputs digital YCbCr for tele-
vision formats.
B Set: SROP 2048
Rst: SROP 0 2048
Reset HDCP Rx gating
clock
Resets the receiver, and gates
off transmitter clock and data.
Outputs Set: SROP 16
Rst: SROP 0 16