Chapter 7 - Connectors

7.2.8 DC power input socket

Caution

The input voltage must not exceed +17 Vdc.

Figure 7-13. DC power input connector

1

2

3

4

1.Ground

2.Ground (internally bridged to pin 1)

3.+11.5 Vdc . . . +17 Vdc (internally bridged to pin 4)

4.+11.5 Vdc . . . +17 Vdc

This socket accepts a DC voltage of 15V nominal.

XLR 4-pin male: panel view (X101)

7.2.9 DC power and tally output socket

Figure 7-14. DC power and tally output connector

12

43

Hirose 4-pole female: panel view (X110)

1.Ground

2.On air

3.No connection

4.+12 Vdc (max. 18W)

Shield of cable directly to the connector housing.

The socket provides access to an internal tally switch. When the camera is on-air, the contact of the internal relay is closed.

7.2.10 Script light power supply socket

Figure 7-15. Script light power supply output connector

1

2

1.+12 Vdc (maximum dissipation 3W)

2.Power return

3.Shield

3

Fischer 3-pole female: panel view (X111)

LDK 8000 HDTV camera system User’s Guide (v3.0)

101

Page 101
Image 101
RCA LDK 8000 manual DC power input socket, DC power and tally output socket, Script light power supply socket