RCA LDK 8000 manual Turns high-pass filter for audio channel 1 on

Models: LDK 8000

1 108
Download 108 pages 10.78 Kb
Page 86
Image 86

Chapter 6 - Menu structure and contents

Install (user 0)

Value(s)

Description

Level

File

 

 

 

 

 

 

 

 

Audio 1 Level

-22dB, -28dB, -34dB,

Sets input gain level for audio channel 1

User 1

Oper

 

 

 

-40dB, -46dB, -52dB,

(when audio gain mode is set to local).

 

 

 

 

 

-58dB, -64dB

 

 

 

 

 

 

 

 

 

 

 

Audio 1 HPF

Off, On

Turns high-pass filter for audio channel 1 on

User 1

Oper

 

 

 

 

or off. Use to reduce 50Hz hum or low

 

 

 

 

 

 

frequency noise.

 

 

 

 

 

 

 

 

 

 

Audio 2 Source

Line, Mic, Mic48, Front

Selects source for audio channel 2.

User 1

Oper

 

 

 

 

 

 

 

 

Audio 2 Level

-22dB, -28dB, -34dB,

Sets input gain level for audio channel 2

User 1

Oper

 

 

 

-40dB, -46dB, -52dB,

(when audio gain mode is set to local).

 

 

 

 

 

-58dB, -64dB

 

 

 

 

 

 

 

 

 

 

 

Audio 2 HPF

Off, On

Turns high-pass filter for audio channel 2 on

User 1

Oper

 

 

 

 

or off. Use to reduce 50Hz hum or low

 

 

 

 

 

 

frequency noise.

 

 

 

 

 

 

 

 

 

Tally

 

 

User 0

 

 

 

 

 

 

 

 

 

Onair Lamp

Enable, Disable

Select disable when the tally light at the

User 0

Oper

 

 

 

 

front of the 7”viewfinder have to follow the

 

 

 

 

 

 

tally signal; select disable if you never want

 

 

 

 

 

 

it to light.

 

 

 

 

 

 

 

 

 

 

Tally Lock

Off, On

Turns tally lock function on or off. When tally

User 3

-

 

 

 

 

lock is on, some camera controls are locked

 

 

 

 

 

 

when camera is on air.

 

 

 

 

 

 

 

 

 

Reverse Scan

 

 

User 0

 

 

 

 

 

 

 

 

 

Reverse Scan

Off, On

Turns reverse scan on or off. Reverse scan

User 0

Scene

 

 

 

 

flips the image and can be used when the

 

 

 

 

 

 

camera is mounted at a rotated angle.

 

 

 

 

 

 

 

 

 

 

Mode

Horiz, Vert, Both

Selects reverse scan mode:

User 0

Scene

 

 

 

 

Horiz = the image is flipped horizontally;

 

 

 

 

 

 

Vert = the image is flipped vertically;

 

 

 

 

 

 

Both = the image is flipped both horizontally

 

 

 

 

 

 

and vertically.

 

 

 

 

 

 

 

 

 

Exposure

 

 

 

 

 

 

 

 

 

 

 

 

Lighting

-10..+10 (0)

Sets the exposure correction to synchronise

User 1

Scene

 

 

 

 

with ambient lighting frequency when

 

 

 

 

 

 

exposure mode is 50 Hz or 60 Hz (not

 

 

 

 

 

 

available in high speed video modes).

 

 

 

 

 

 

 

 

 

 

Clean Scan

 

 

User 1

-

 

 

 

 

 

 

 

 

 

Cl.Scan Mode

Extended, Normal

Selects clean scan mode:

User 1

-

 

 

 

 

Normal = shutter is running (no smear);

 

 

 

 

 

 

Extended = shutter is not running (more

 

 

 

 

 

 

accurate clean scan but possible vertical

 

 

 

 

 

 

smear).

 

 

 

 

 

 

 

 

 

 

 

Value

50.6.. 103.1 Hz (50 Hz)

Select clean scan frequency.

User 1

-

 

 

 

54.7 .. 121.5 Hz (60 Hz)

 

 

 

 

 

 

122.0 .. 200.0 Hz (high

 

 

 

 

 

 

speed modes)

 

 

 

 

 

 

 

 

 

 

 

 

Units

Hz, mSec

Selects display units for clean scan.

User 1

-

 

 

 

 

 

 

 

Gain Preset

 

 

User 2

 

 

 

 

 

 

 

 

 

Gain - (dB)

-3dB, -6dB

Selects gain value for - preset.

User 2

Oper

 

 

 

 

 

 

 

 

Gain + (dB)

3dB, 6dB, 9dB

Selects gain value for + preset.

User 2

Oper

 

 

 

 

 

 

 

86