INSTALLATION

REGENCY DIRECT VENT SYSTEM (FLEX)

HORIZONTAL TERMINATIONS ONLY

This venting system, in combination with the P33-3 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram on page 10.

Regency Direct Vent (Flex) System Termination Kit (Part # 946-513) includes all the parts needed to install the P33-3 with a maximum

run of 2 feet. If installing the P33 with a continuous vent length of more than 2 ft (.6m) to a maximum of 10 ft. (3.0m) using Kit # 946-515 (4 ft) or 946-516 (10 ft) or see page 13 for alternate venting arrangements.

1)6-7/8" dia. fl exible liner (2 ft. length)

2)4" dia. fl exible liner (2 ft. length)

3)spring spacers (3)

4)thimble (2)

5)AstroCap termination cap (1)

6)screws (12)

7)tube of Mill Pac (1)

8)plated screws (8)

9)screws #8 x 1-1/2" drill point, stainless steel (4)

Notes:

1)Liner sections should be continuous without any joints or seams.

2)Only Flex pipe purchased from Regency may be used for Flex installations.

 

Wall Thimble (2 pc)

 

(required in

 

Canada only)

 

AstroCapTM

4" (102mm)

Termination Cap

dia. flue pipe

(Part# 946-523/P)

 

See also

 

Figure 1 below.

 

spring

 

spacer

Important

If using any Cabinet Mantels with Part

#510956, 510958, 510962, 510964 and 510834 the wall thimble must be secured fi rst and venting must be attached to unit before sliding into fi nal position.

Also Simpson Dura-Vent venting can- not be used with any of the mantels

noted above.

Minimum

Simpson Dura-Vent Center-Line

6-7/8"

(173mm) dia. Flue pipe

Minimum Flex Kit Center-Line

Alternate Hori-

zontal Termi-

nation Caps

Figure 1

Wherever necessary due to external location of cap, the AstroCapcan be replaced with the FPI Riser Vent Termination Cap or the Dura-Vent Snorkel Termination Cap.

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace

Page 11