Regency P33-LP3, P33-NG3 Horizontal Venting with Two 2 90o Elbows, Option, H + H1

Models: P33-NG3 P33-LP3

1 48
Download 48 pages 9.74 Kb
Page 18
Image 18
Horizontal Venting with Two (2) 90o Elbows

INSTALLATION

Horizontal Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Horizontal Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

 

V

H + H1

 

 

 

 

A)

1'

Min.

3' Max.

B)

2'

Min.

4' Max.

C)

3'

Min.

5' Max.

D)

4'

Min.

6' Max.

E)

5'

Min.

7' Max.

F)

6'

Min.

8' Max.

 

 

 

 

 

 

 

 

With these options, maxi- mum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal.

Please note minimum 1 foot between 90o elbows is required.

Option

 

H

 

V

H + H1 + H2With these options, max.

A)

 

1 Max.

 

1' Min.

3' Max.

total pipe length is 30 feet

B)

 

2' Max.

 

3' Min.

5' Max.

with min. of 11 feet total

 

 

 

 

 

 

vertical and max. 9 feet

C)

 

3' Max.

 

5' Min.

6' Max.

 

 

total horizontal.

 

 

 

 

 

 

D)

 

4' Max.

 

7' Min.

7' Max.

 

 

Please note min.

 

 

 

 

 

 

E)

 

5' Max.

 

9' Min.

8' Max.

1 foot between 90o

 

 

 

 

 

 

elbows is required.

F)

 

6' Max.

 

11' Min.

9' Max.

 

 

 

 

 

 

 

Horizontal Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

H

V

H + H1

 

With these options, max.

 

 

 

 

total pipe length is 30 feet

A)

1' Max.

1' Min.

3' Max.

 

 

 

 

 

 

with min. of 8 feet total

B)

2' Max.

2' Min.

5' Max.

 

 

 

 

 

vertical and max. 8 feet

C)

3' Max.

4' Min.

6' Max.

 

total horizontal.

D)

4' Max.

6' Min.

7' Max.

Please note min. 1 foot

 

 

 

 

between 90o elbows is

E)

5' Max.

8' Min.

8' Max.

 

 

 

 

 

required.

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace

Page 18
Image 18
Regency P33-LP3 Horizontal Venting with Two 2 90o Elbows, Horizontal Venting with Three 3 90o Elbows, Option, H + H1