INSTALLATION

Conversion Kit from Natural Gas to Propane Model #431-969

for P33-3 using SIT 820 NOVA Gas Valve

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER

IF IN DOUBT DO NOT DO THIS CONVERSION !!

Conversion Kit Contains:

Qty. Part #

Description

1910-018 SIT Conversion Kit-50% Turndown LP

1910-037 LP Injector (Pilot Orifi ce)

1904-163 Burner Orifi ce #54

1908-255 Decal "Converted to Propane"

1908-528 Red "PROPANE" label

1908-529 5/32" Allen Key

1908-812 Instruction Sheet

1)Shut off the gas supply.

2)Remove the louvers (and bay door if it is installed).

3)Open the fl ush door and remove the door.

4)Remove the logs and embers/rockwool.

5)Remove the 2 screws holding the Burner Assembly to the fi rebox base. Push the Burner Assembly to the left and lift out.

7)Unscrew the pilot orifi ce with the allen key and replace with the LP pilot orifi ce in the kit and replace pilot cap.

8)Remove burner orifi ce with a 1/2" wrench and discard. Use another wrench to hold on to the elbow behind the orifi ce.

Burner Orifi ce

Remove the 2 screws, push Burner

Assembly to the left and lift out.

9) Reinstall new burner orifice LPstamped #54

6) Pull off the pilot cap to expose the pilot and tighten. orifi ce.

10) Remove and discard the 3 pressure regula- tor mounting screws (A), pressure regulator tower (B) and diaphragm (C).

11) Insure that the rubber gasket (D) is properly positioned and install the new HI/LO pres- sure regulator assembly to the valve using the new screws (E) supplied with the kit. Tighten screws securely.

12) Reverse steps 5) to 2).

13) Attach clear label "This unit has been con- verted to Propane" near or on the serial # decal. Attach white label "This valve has been converted from NG to LPG using SIT conversion Kit Code 0.907.202" onto the valve.

14)Replace yellow "Natural Gas" label with red "Propane" label

15)Check for gas leaks.

16)Check inlet and outlet pressures.

17)Check operation of fl ame control.

18)Check for proper fl ame appearance and glow on logs.

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace

Page 26
Image 26
Regency P33-LP3, P33-NG3 installation manual Conversion Kit Contains