RIGID PIPE VENTING SYSTEMS

INSTALLATION

RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations

The minimum components required for a basic horizontal termination are:

1AstroCap Horizontal Termination Cap

145o Elbow

1Rigid Pipe Adaptor

1Wall Thimble

1Length of pipe to suit wall thickness (see chart)

Vertical

Terminal

Storm Collar

Vinyl Siding

Standoff (Optional)

Flashing

For siding other than vinyl furring strips may be

used, instead of the vinyl siding standoff, to create Ceiling Firestop a level surface to mount the vent terminal. The

Terminal must not be recessed into siding.

Horizontal

Termination

Cap

If a Vinyl Siding Standoff is required (it must be

 

Wall Thimble

 

 

 

 

used with vinyl siding), measure to outside surface

Pipe Length

Adj.Pipe Length

 

of wall without siding and add 2 inches.

 

11" - 14-5/8"

 

 

(279mm - 372mm)

Horizontal

 

90o Elbow

 

Termination Cap

 

 

 

Alternate Hori-

24" (610mm)

 

zontal Termi-

 

Pipe Length

Vinyl Siding

nation Caps

 

Standoff (Optional)

 

 

Wall Thimble

 

 

Adj.Pipe Length

 

 

11" - 14-5/8"

 

 

45o Elbow (279mm - 372mm)

 

 

Rigid Pipe Adaptor

 

 

 

WARNING:

 

 

 

Do not combine venting components from

 

 

different venting systems.

 

However use of the the AstroCapTM and FPI

Riser is acceptable with all systems.

 

 

 

 

 

 

This product has been evaluated by Intertek for

 

 

 

 

 

 

using a Dura-Vent Flue Adaptor in conjunction

 

 

Flat Wall Installation

 

 

with Selkirk Direct-Temp and Ameri Vent Direct

Max. Wall
Vent Length

 

 

venting systems. Use of these systems with the

 

 

Direct Vent GS starting collar is deemed accept-

Thickness (inches)
Required (inches)

 

 

able and does not affect the Intertek WHI listing

 

 

 

7-1/4"

6"

 

 

 

 

 

of components.

 

 

10-1/4"

9"

 

 

 

 

 

 

 

 

 

 

 

 

13-1/4"

12"

 

 

When using piping other than Simpson

 

12-1/4"

-

15-7/8"

11" - 14-5/8" Adj. Pipe

 

Dura-Vent, 3 screws must be used to

 

18-1/4"

-

25-1/4"

11" - 14-5/8" Adj. Pipe

 

secure rigid pipe to adaptor.

 

 

 

 

 

 

 

 

 

 

 

 

The FPI AstroCapTM and FPI Riser Vent terminal is certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent®, Direct Vent GS, American Metal Products, Ameri Vent Direct vent and Selkirk Direct-Temp. FPITM, and FPI AstroCapTM are the proprietary trademarks of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace

Page 13