Regency P33-NG3, P33-LP3 installation manual Vertical Termination With Co-Linearflex System

Models: P33-NG3 P33-LP3

1 48
Download 48 pages 9.74 Kb
Page 21
Image 21
VERTICAL TERMINATION

INSTALLATION

VERTICAL TERMINATION

WITH CO-LINEAR FLEX SYSTEM

THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE.

This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney. See the Venting Arrangements on next page for minimum and maximum heights.

Required Parts:

Part #

Description

946-529

Co-linear DV Vertical

 

Termination Cap

948-305

3" Flex - 35 ft.

946-563

Co-Axial to Co-Linear Adapter

Kit

 

 

which contains the following:

 

Co-linear Flex Adapter

 

Outer Pipe

 

Inner Pipe Adapter

510-994

Rigid Pipe Adaptor

Masonry chimneys may take various contours which the fl exible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

Co-linear DV

 

Vertical Termination

 

Cap # 946-529

 

A maximum

 

of two certified

 

joiner kits

 

may be used

 

per length.

Flex Liner

#948-305

 

35 ft (11m)

 

94545o Elbow

Alternate Approved Caps

980Vertical Termination Cap

991High Wind Cap

923GK 3" Co-linear Adapter with fl ashing

FPI Cabinet and/or Flat Wall Mantles may be used in these applications en- suring that clearances to combustibles are maintained.

Exhaust

Flue

Outer

Pipe

with Kit# 946-563

Pipe Length

Air Intake

Rigid Pipe Adaptor

# 510-994

45o Elbow

Inner Pipe

Adapter with Kit# 946-563

Co-Linear

Flex

Adapter with Kit# 946-563

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace