INSTALLATION

Horizontal Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option V

H

V + V1 H + H1

A)2' Min. 1' Max. 3' Min. 4' Max.

B)3' Min. 2' Max. 4' Min. 5' Max.

C)4' Min. 3' Max. 6' Min. 6' Max.

D)5' Min. 4' Max. 8' Min. 7' Max.

E)6' Min. 5 Max. 10' Min. 8' Max.

F)7' Min. 6' Max. 12' Min.

With these options, max. total pipe length is 30 feet with min. of 12 feet total vertical and max. 9 feet total horizontal.

Please note min. 1

foot between 90o 9' Max.

elbows is required.

Vertical Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option V

H

V + V1 With these options, max. total

A)1' Min. 4' Max. 2' Min. pipe length is 30 feet with min.

B)

2' Min.

5' Max.

3' Min.

of 6 feet total vertical and max.

8 feet total horizontal.

C)

3' Min.

6' Max.

4' Min.

Please note min. 1 foot

D)

4' Min.

7' Max.

5' Min.

between 90o elbows is re-

E)

5' Min.

8' Max.

6' Min.

quired.

Vertical Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

H + H1

V

With these options, max. total

 

 

 

A)

2' Max.

2' Min. pipe length is 30 feet with min.

B)

3' Max.

3' Min. of 6 feet total vertical and max.

C)4' Max. 4' Min. 6 feet total horizontal.

Please note min. 1 foot

D)5' Max. 5' Min. between 90o elbows is

E)6' Max. 6' Min. required.

Foradditionalverticalventingwith2 x 90o elbows, refer to page 15.

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace

Page 19
Image 19
Regency P33-NG3, P33-LP3 Vertical Venting with Two 2 90o Elbows, Option + V1 H + H1, + V1 With these options, max. total