The P33-3 is approved for a maximum 40 ft. straight vertical, with rigid pipe vent systems for Propane and Natural Gas.

INSTALLATION

The P33-3 is approved for a maximum 40 ft. straight vertical, with rigid pipe vent systems for Propane and Natural Gas.

The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations with rigid pipe vent systems for Propane and Natural Gas. Maximum two 45o elbows allowed.

Vent must be supported at offsets.

Firestops are required at each floor level and whenever passing through a wall.

Maintain clearances to combustibles.

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace