Regency P33-NG3, P33-LP3 Optional Wall Switch, Wall Thermostat, Remote Control, to 120V wire

Models: P33-NG3 P33-LP3

1 48
Download 48 pages 9.74 Kb
Page 33
Image 33
OPTIONAL

INSTALLATION

OPTIONAL

OPTIONAL

WALL THERMOSTAT

REMOTE CONTROL

OPTIONAL

WALL SWITCH

A wall thermostat may be installed if desired, connect the wires as per the wiring diagram. Use table below to determine the maximum wire length.

Note: Preferableifthethermostatisinstalled on an interior wall.

Regency offers an optional programmable thermostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or UL approved may be used.

CAUTION

Do not wire millivolt wall thermostat wires to 120V wire.

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

 

Wire Size

Max. Length

 

 

 

 

 

 

 

14 GA.

50

Ft.

 

 

16 GA.

32

Ft.

 

 

18 GA.

20

Ft.

 

 

20 GA.

12

Ft.

 

 

22 GA.

9

Ft.

 

 

 

 

 

 

Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter, a receiver and a wall mount- ing plate.

1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fi replace to that location. Use Thermostat Wire Table.

2)Connect the two wires to the gas valve. See diagram below.

CAUTION

Do not wire millivolt remote control wires to 120V wire.

3)Install 3AAAalkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.

1)Runthesupplied15'ofwirethroughtheright or left side gas inlet opening. Be careful not to damage wire.

Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run, use the Thermostat Wire Table.

2)Connect the wire to the supplied wall switch and install into the receptacle box.

CAUTION

Do not wire millivolt

wall switch wire

to 120V wire.

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace

Page 33
Image 33
Regency P33-NG3, P33-LP3 Optional Wall Switch, Wall Thermostat, Remote Control, Do not wire millivolt wall switch wire