Regency P33-LP3, P33-NG3 Removing Valve, Installing Valve, 1Shut off the gas supply

Models: P33-NG3 P33-LP3

1 48
Download 48 pages 9.74 Kb
Page 40
Image 40
REMOVING VALVE

MAINTENANCE

REMOVING VALVE

1)Shut off the gas supply.

2)Remove the louvers (and bay door if it is on).

3)Open the fl ush door and remove the door.

4)Remove the logs.

5)Remove the burner/grate assembly by removing the two Phillips head screws and then lift the burner assembly out.

10)Undo the pilot tube from the valve with a 7/16" wrench.

INSTALLING VALVE

1)

Attach the valve to the valve bracket with

 

the 4 (m5x8 metric) screws provided.

2)

Reconnect the "gas out" fl are fi tting with

 

an 11/16" wrench.

3)

Reconnect the "gas out" fl are nut with a

 

13/16" wrench.

4)

Install piezo ignitor push button assembly

 

and reconnect wire.

5)

Reconnectthequickdropoutthermocouple

 

nut with a 9mm wrench.

Diagram 3: Lift out Valve Tray Assembly

6) Reconnect the pilot tube nut with a 7/16"

wrench.

7) Scrapeofftheoldgasketfromthefloorofthe

fi rebox and from the valve tray assembly.

8)Install a new gasket and reinstall the valve tray assembly.

Diagram 1: Remove the left and right screws and then lift out the burner/grate assembly.

6)Remove the rear log stand by removing the 2 screws.

7)Disconnect the inlet gas line. See diagram 2.

8)Disconnect the 2 TP wires and the 2 TH wires from the valve.

9)Remove the 10 Phillips head screws secur- ingthevalvetrayassemblyinplace(diagram

2)and then lift the entire assembly out

(diagram 3).

screws

11)Undo the quick drop out thermocouple nut on the valve with a 9mm (metric) wrench.

12)Remove the Piezo igniter wire and push button assembly.

13)Undo the "gas out" fl are nut with a 13/16" wrench.

14)Undo the "gas out" fl are fi tting with an 11/16" wrench.

15)Remove the 4 Phillips head screws from the sides of the valve bracket and remove valve.

Hint: If you are using black pipe, ensure that there is a union by the valve, otherwise removal will be almost impossible.

Rear Log Stand

Note: Failure to install a new gasket may severely affect the appliance per- formance.

9)Reinstall the 10 hold down screws.

10)Hook up the 2 TP and 2 TH wires to the appropriate connections on the valve.

11)Reinstall the front log stand.

12)Install Burner/grate assembly.

13)Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector. (Do not use open fl ame for leak testing.)

14)Fire up the unit temporarily.

15)Check the manifold pressure.

16)Reinstall the logs and brick panels as needed.

17)Close the door and replace the louvers.

18)Fire up the unit again and check for proper fl ame appearance and glow on logs.

screwsValve Tray Assembly Diagram 2: Rear Log Stand & Valve Tray Assembly

Regency P33-3 Zero Clearance Direct Vent Gas Fireplace

Page 40
Image 40
Regency P33-LP3 Removing Valve, Installing Valve, 1Shut off the gas supply, Diagram 3 Lift out Valve Tray Assembly