AX2500/2850’s Inputs and Outputs

AX2500/2850’s Inputs and Outputs

In addition to the RS232 and R/C channel communication lines, the AX2500/2850 includes several inputs and outputs for various sensors and actuators. Depending on the selected operating mode, some of these I/Os provide feedback and/or safety information to the con- troller.

When the controller operates in modes that do not use these I/O, these signals become available for user application. Below is a summary of the available signals and the modes in which they are used by the controller or available to the user.

TABLE 11. AX2500/2850 I/O functions

Signal

I/O type

Use

Activated

 

 

 

 

Out C

2A Digital Output

User

Always active. Activated using R/C channel 3 (R/C

 

 

defined

mode), or serial command (RS232 mode)

 

 

 

 

Out D

Low Current

User

Always active. Activated using R/C channel 3 (R/C

 

Digital Output

defined

mode), or serial command (RS232 mode) - (Not

 

 

 

available on AX2850)

 

 

 

 

Inp F

Digital Input

User

Active in RS232 mode only. Read with serial com-

 

 

defined

mand (RS232)

 

 

 

 

 

 

Activate

When Input is configured to drive Output C

 

 

Output C

 

 

 

 

 

 

 

Turn FETs

When Input is configured as “dead man switch”

 

 

On/Off

input

 

 

 

 

Inp E

Digital Input

Same as Input F - (Not available on AX2850)

 

 

 

 

EStop/Invert

Digital Input

Emer-

When Input is configured as Emergency Stop

 

 

gency stop

switch input.

 

 

 

 

 

 

Invert

When Input is configured as Invert Controls

 

 

Controls

switch input.

 

 

 

 

 

 

User

When input is configured as general purpose.

 

 

defined

Read with serial command (RS232).

 

 

 

 

Sensor 1

Analog Input

Tachome-

When Channel 1 is configured in Closed Loop

 

 

ters input

Speed Control

 

 

 

 

 

 

Position

When Channel 1 is configured in Closed Loop

 

 

sensing

Position Control

 

 

 

 

 

 

Tempera-

When Channel 1 is configured is Open Loop

 

 

ture sensor

Speed Control and Motor Temperature protection

 

 

 

is enabled

 

 

 

 

 

 

User

When Channel 1 is configured as Open Loop

 

 

defined

Speed Control and Temperature protection is dis-

 

 

 

abled. Read with serial command (RS232).

 

 

 

 

Sensor 2

Analog Input

Same as Sensor 1

 

 

 

 