RoboteQ AX2550/2850 user manual Connecting Switches or Devices to Input E

Models: AX2550/2850

1 180
Download 180 pages 6.28 Kb
Page 55
Image 55

Connecting Switches or Devices to Input E

This output is not available on the AX2850 or on the AX2550 with the Encoder Mod- ule installed.

Connecting Switches or Devices to Input E

Input E is a general purpose, digital input. This input is only active when in the RS232 and Analog modes. In R/C mode, this line is used as the radio channel 3 input.

Input E is a high impedance input with a pull-up resistor built into the controller. Therefore it will report an On state if unconnected, and a simple switch as shown on Figure 25 is nec- essary to activate it.

+5V Out 14

Input E 8

Ground 5

10kOhm

10kOhm

AX2500 Internal Buffer and Resistors

FIGURE 25. Switch wirings to Input E

The status of Input E can be read in the RS232 mode with the ?i command string. The con- troller will respond with three sets of 2 digit numbers. The status of Input E is contained in the first set of numbers and may be 00 to indicate an Off state, or 01 to indicate an On state.

This input is not available on the AX2850 or on the AX2550 with the Encoder Module installed.

Connecting Switches or Devices to Input F

Input F is a general purpose digital input. This input is only active when in the RS232 mode. In R/C mode, this line is used as the radio channel 2 input.

Input F is an opto-coupled input and requires the opto coupler buffer to be powered for it to work. Figure 26 below shows how to wire the buffer’s power inputs (+5V In, GND In). Seen from the outside, Input F is similar to input E, but with a lower impedance of 10kOhm. If left unconnected, this input will report an Off state. As a result, this input may

AX2500/2850 Motor Controller User’s Manual

55

Page 55
Image 55
RoboteQ AX2550/2850 user manual Connecting Switches or Devices to Input E, Connecting Switches or Devices to Input F