Fault Messages

TABLE 14. Motor Commands and resulting display

Possible Display

Motor 1

Motor 2

Comment

 

 

 

 

 

 

Forward

Reversed

 

 

 

Reversed

Reversed

 

 

 

 

 

 

 

 

 

 

 

 

MOSFET Transistors are OFF

Will occur during Overvolt-

 

 

 

 

 

 

Motors are freewheeling

age or Undervoltage condi-

 

 

 

 

 

tions (see page 32), of if

 

 

 

 

 

Dead-man switch is acti-

 

 

 

 

 

vated (see page 46)

 

 

 

 

 

Fault Messages

The AX2500/2850 uses the LED display to report fault conditions. When these messages are displayed, the motors are normally stopped.

No Control

This message is displayed in the R/C mode to indicate that no valid radio signal has been detected at its inputs, or that radio signal has been lost. When the controller is configured in the mixed mode, signals on channel 1 and channel 2 must be present to enable the con- troller. When the controller is configured in the separate mode, a signal received on either channel will enable the controller. When enabled, the controller will display the normal motor status described previously.

The “no control” messages is displayed using the following sequence of digits.

FIGURE 36. No Radio signal scrolling message

AX2500/2850 Motor Controller User’s Manual