AX2500/2850 Quick Start

FIGURE 5. “no control” scroll message indicates no valid R/C signal is present

Turn the R/C transmitter On. The “no ctrl” scrolling message will disappear and the display will show steady patterns depending on the motors’ selected direction.

Move the joystick on the transmitter to activate the motors to the desired speed and direc- tion.

See “R/C Operation” on page 69 of the User’s Manual for a detailed description of the many features and options available in the R/C mode.

Button Operation

The AX2500/2850 has three buttons: Set, Program and Reset. These buttons are not needed for normal operation, as the controller is immediately operational upon power up.

The Reset button will restart the controller. This button is recessed and you will need a paper clip to press it. Reset is also accomplished by turning the controller’s power Off and back On.

The Set and Program buttons have the following functions depending how and when they are pressed:

TABLE 2. AX2500/2850 Buttons Function

Prog and Set button status

Function

 

 

Press and hold Program alone during reset or power up

Enter the Programming Mode.

 

 

Press and hold Set alone during reset of power up

Enter Self-Test mode. See Self-Test

 

Mode” on page 47 of the User’s Manual

 

 

Press and hold Program and Set together during reset or

Reset configuration parameters to factory

power up

default

 

 

Press Program while Programming Mode

Accept previous parameter change and

 

select next parameter

 

 

Press Set while in Programming mode

Change value of selected parameter

 

 

Press Program pressed alone during normal operation

No effect

 

 

Press Set alone during normal operation

No effect

 

 

Press Program and Set together during normal operation

Emergency stop

 

 

16

AX2500/2850 Motor Controller User’s Manual

Version 1.7. February 1, 2005

Page 16
Image 16
RoboteQ AX2550/2850 user manual Button Operation, Prog and Set button status Function