Normal and Fault Condition LED Messages

Motor Direction Status

When the controller is running, two pairs of LED segments are directly related to com- mand informations to the Power Output stage. The position and meaning of the segments is shown in the figure below.

Motor 2

 

Lit: Forward

Direction

 

Off: Reverse

 

FIGURE 1. Each command bit is wired to 2 LED segments

Motor 1

 

Lit: Forward

Direction

 

Off: Reverse

 

Note that the display does not provide Power information. Therefore it is possible that the motor be stopped while the display indicates that the direction is forward. In such a situa- tion is set to apply the power in the forward direction to the output stage but the motor is stopped because the applied power is zero.

The LED can display a total of 5 patterns summarized in Table 14.

TABLE 14. Motor Commands and resulting display

Possible Display

Motor 1

Motor 2

Comment

Is also displayed when con- troller is active with a 0 com- mand on each channel (i.e. motors at speed 0)

Forward

Forward

Reversed

Forward

66

AX2500/2850 Motor Controller User’s Manual

Version 1.7. February 1, 2005

Page 66
Image 66
RoboteQ AX2550/2850 Motor Direction Status, Normal and Fault Condition LED Messages, Possible Display Motor Comment