RoboteQ AX500 manual Amps Limit, Bit Definition See pages

Models: AX500

1 154
Download 154 pages 41.77 Kb
Page 115
Image 115

Accessing & Changing Configuration Parameter in Flash

This parameters selects the various open loop and closed loop operating modes as well as the feedback method.

Bit

Definition

 

 

See pages

2:0

Motor Control Mode

0 = A & B separate speed open loop

page 36

 

 

(default)

page 73

 

 

 

 

 

 

1

= A & B mixed speed open loop

page 63

 

 

 

 

 

 

2

= A speed open loop, B position

 

 

 

3

= A & B position

 

 

 

4

= A & B separate speed closed loop

 

 

 

5

= A & B mixed speed closed loop

 

 

 

6

= A speed close loop, B position

 

 

 

 

 

 

6:3

Reserved

 

 

 

 

 

 

 

6

Ch1 Feedback type

0 = Analog

page 73

 

 

1

= Encoder

page 63

 

 

 

 

7

Ch2 Feedback type

0 = Analog

 

 

 

1

= Encoder

 

 

 

 

 

 

Amps Limit

Address:

^02

Access:

Read/Write

Effective:

After Reset or ^FF

This parameter configures the controller’s Amps limit. Note that this limits the amps flow- ing out of the power supply. Current flowing through the motors may be higher.

Bit

Definition

 

 

See pages

 

 

 

 

3:0

Coarse Amps

0 = 3.75A

page 38

 

 

1

= 5.625A

 

 

 

2

= 7.5A

 

 

 

3

= 9.375A

 

 

 

4

= 11.25A

 

 

 

5

= 13.125A (default)

 

 

 

6

= 15A

 

 

 

 

 

7:4

Fine Amps

Mutliply this number by 0.125 and sub-

 

 

 

stract result from the Coarse Amps value

 

 

 

 

 

 

AX500 Motor Controller User’s Manual

115