RoboteQ AX500 manual Mounting Considerations, Thermal Considerations, Mechanical Specifications

Models: AX500

1 154
Download 154 pages 41.77 Kb
Page 150
Image 150

Mechanical Specifications

4.20"

(106.7mm)

 

4.20" (106.7mm)

 

0.15" (3.8mm)

 

0.15" (3.8mm)

 

 

0.15"

 

0.15"

 

(3.8mm)

(3.8mm)

 

 

 

1.25"

 

 

(31.75mm)

 

 

 

2.00"

 

 

(50.8mm)

 

 

1.10"

 

 

(74.0mm)

 

0.15"

 

 

(3.8mm)

 

 

0.15" (3.8mm)

1.875" (47.6mm)

0.15" (3.8mm)

 

2.90" (73.7mm)

 

FIGURE 86. AX500 top view and dimensions

Mounting Considerations

The AX500’s heatsink is located at the bottom of the board. This requires therefore that the board be mounted with spacers that are at minimum 0.6” (15mm).

0.6" (15mm) or longer spacer

FIGURE 87. Use spacers to provide clearance for heatsink

Thermal Considerations

When mounting the board, and if current is expected to be above 7A on average, ensure that there can be a natural or forced convection flow to remove the heat. Mounting the

150

AX500 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

Page 150
Image 150
RoboteQ AX500 manual Mounting Considerations, Thermal Considerations, Mechanical Specifications