Controller is on, Radio is turned Off (or Radio On with RC ch3 Off)

Relay deactivates. RS232 is now connected to shared input.

String of Carriage Returns now received by controller.

Computer looks for OK prompt to detect that the RS232 mode is now active.

Note: Wait 5 seconds for the capacitor to discharge before attempting to switch to RC mode if doing this repeatedly. Controller will not reset otherwise.

Analog and R/C Modes Data Logging String Format

When the controller is configured in R/C or Analog mode, it will automatically and continu- ously send a string of ASCII characters on the RS232 output.

This feature makes it possible to log the controller’s internal parameters while it is used in the actual application. The data may be captured using a PC connected via an RS232 cable

FIGURE 1. Pin orlocationswirelessonmodemthe contorollerinto’sa 15PDA-pininstalledconnectorin the actual robot. Details on how to wire the DB15 connector is described on page 92 for the R/C mode and on page 99 for the Analog mode.

This string is composed of a start character delimiter, followed by two-digit Hexadecimal numbers representing internal parameter values, and ending with a Carriage Return charac- ter. The figure below shows the structure of this string.

 

 

miter

1

2

ower

1

2

1

 

2

 

 

 

1

2

 

Volts

Volts

pd/Pos

er

 

 

 

 

ower

In

 

In

 

 

 

 

 

 

 

 

 

 

 

Start

CommCommandOutputOutput

Analog Analog

Amps

Amps

 

TemperatureMain Internal EncoderEnd

 

 

 

 

Temperature

 

Bat

 

 

S

Delimit

 

 

Deli

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

P

 

 

 

 

1

2

 

 

 

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: 00 11 22 33 44 55 66 77 88 99 AA BB CC

FIGURE 71. ASCII string sent by the controller while in R/C or Analog mode

The hexadecimal values and format for each parameter is the same as the response to RS232 queries described in page 107.

Characters are sent by the controller at the rate of one every 8ms. A complete string is sent in.