Serial (RS-232) Controls and Operation

Acceleration

Address:

^03

Access:

Read/Write

Effective:

After Reset or ^FF

This parameter configures the rate at which the controller internally changes the command value from the one it was to the one just received.

Bit

Definition

See pages

 

 

 

7:0

0 = very slow

See “Programmable Acceleration”

 

1

= slow

on page 40 for complete list of

 

acceptable values

 

(2) = medium-slow (default)

 

 

 

3

= medium

 

 

4

= fast

 

 

5

= fastest

 

 

 

 

 

Input Switches Function

 

Address:

^04

 

 

 

Access:

Read/Write

 

 

 

Effective:

After Reset or ^FF

 

 

 

This parameter enables and configures the effect of the controller’s Digital Inputs and other

 

settings.

 

 

 

 

 

 

 

 

 

 

Bit

Definition

 

 

See pages

 

 

 

 

 

 

 

1:0

Enable and

 

(00) = Input Disabled (default)

page 45

 

 

Configure

 

01 = Input as Emergency Stop

page 45

 

 

Invert/Estop

 

 

 

 

10 = Disabled

 

 

 

 

 

 

 

 

 

 

11 = Input as Invert Command

 

 

 

 

 

 

 

 

2

Output C when

 

(0) = No Action (default)

page 45

 

 

Motor On

 

1 = Output C On when either motor is On

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Encoder Safety

 

Unavailable

 

 

 

 

 

 

 

 

116

AX500 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

Page 116
Image 116
RoboteQ AX500 manual Acceleration, Input Switches Function