RoboteQ AX500 manual Connecting to the Batteries and Motors

Models: AX500

1 154
Download 154 pages 41.77 Kb
Page 15
Image 15

Connecting to the Batteries and Motors

Connecting to the Batteries and Motors

Connection to the batteries and motors is shown in the figure below and is done by con- necting wires to the controller’s terminal strip.

Motor2

 

 

+

 

Power on/off switch

 

-

 

-

 

+

Motor1

Fuse

 

VMot

M1+

M1-

VCon GND GND

GND

M2-

M2+

VMot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12V to 24V

 

 

 

Controller

 

 

 

 

 

 

Motor Battery

Notes:

-The Battery Power connection are doubled in order to provide the maximum current to the controller. If only one motor is used, only one set of motor power cables needs to be connected.

-Typically, 1 or 2 x 12V batteries are connected in series to reach 12 or 24V respectively.

FIGURE 3. AX500 Electrical Power Wiring Diagram

1- Connect each motor to one of the two M+ and M- terminal pairs. Make sure to respect the polarity, otherwise the motor(s) may spin in the opposite direction than expected

two of the three Ground terminals2- Connect the VCon terminal (powering the controller’s internal circuits) through a power switch to the main battery. Connect the VMot terminals (powering the output drivers) directly and permanently to the positive battery terminal.

VCon may be connected to a separate battery to ensure that the controller stays alive even as the battery powering the Motors discharges. Motors will turn only if voltage is present on both VCon and VMot. Refer to the chapter “Connecting Power and Motors to the Controller” on page 25 for more information about batteries and other connection options.

The two are connected to each other inside the controller. The same is true for the. You should wire each pair together as shown in the diagram above.

Important Warning

Do not rely on cutting power to the controller for it to turn off if the Power Control is left floating. If motors are spinning because the robot is pushed are pushed or because of inertia, they will act as generators and will turn the controller, possibly in an unsafe state. Always use the switch on the VCon terminal to power the controller On or Off.

AX500 Motor Controller User’s Manual

15

Page 15
Image 15
RoboteQ AX500 manual Connecting to the Batteries and Motors