6Spot-out Monitoring
Spot-out Monitoring has nothing to do with Live Screen Output, monitoring the full screen of a certain channel. If you select Monitoring in the MENU screen, you can make a channel among CH1 to CH8 spot out or you can output channels one by one at an interval as Screen change Mode of Live Mode. The interval is as same as the forwarding time of Screen change Mode of Live Mode. If you set Spot-out Event Monitoring to On, you will be able to spot out the event channel. In case of simultaneous event occurrence at more than one channel, the lowest numbered event channel has the first priority to be spotted out.
Caution
If the built-in HDD is not connected, or it operates with power applying in error,
( ) indicating "built-in HDD error" is displayed at the top of left. At this time,
(1)Live screen mode
(2)Monitoring mode by Smart Viewer
operate only and the other functions including recording, search, playback, menu setup, and PTZ do not operate.
If the above problem is occurred, Be sure to contact a service center to settle the problem.
Caution
If the fan of set is not operated or occurs an error, the following error message is popped up in the live screen. And the fan error icon is displayed at the left upper. Check the fan of set in this time. The left upper icon is disappeared automatically if the fan operates normally.
Fan Information
Fan is in trouble.
Refer to the Manual.
English 4-8