Quality

Recording resolution will be determined. VH(Very High) / H(High) / S(Standard) / L(Low).

Note

"Full D1" setup for the resolution is available from the recording sheet number of 7.5ips(NTSC)/6.25ips(PAL)

"Half D1" setup for the resolution is available from the recording sheet number of 15ips(NTSC)/12.5ips(PAL)

Resolution “CIF” can be set from Recording page number “30.”

Rate

Determines Frame Rate to be recorded. Frame Rate means the number of screen recorded every second.

Set to 30ips(NTSC)/25ips(PAL), the system records too many screens per second and play continues intermittently since recording is more detailed. This is appropri- ate for concentrated monitoring zone setup.

Set to the one of 30ips / 15ips / 10ips / 7.5ips / 5ips / 3ips / 1ips(NTSC)

Set to the one of 25ips / 12.5ips / 8.33ips / 6.25ips / 5ips / 2.5 ips / 1ips(PAL)

Pre-Event (PreEve.)

Pre-Event Section

Event occurred point of time

Records the situation until Event is issued.

Off : No recording

5sec / 10sec / 20sec / 30sec : The recording time options before Alarm issue

Post-Event (PostEve.)

Post-Event Section

Event occurred point of time

Records the situation since Event is issued.

Off : No recording

5sec / 10sec / 20sec / 30sec / 1min / 3min / 5min / 10min / 20min : To this, the recording time after Alarm issue is set.

English 5-20

Page 65
Image 65
Samsung SHR-4081P manual Quality, Pre-Event PreEve, Post-Event PostEve