Sanyo vcc-zm300p Parts Names And Functions, Control terminals3, 4Menu setting button SET See p8

Models: vcc-zm300p

1 55
Download 55 pages 8.52 Kb
Page 5
Image 5
PARTS NAMES AND FUNCTIONS

PARTS NAMES AND FUNCTIONS

Control

terminals3

SET

4

4Menu setting button (SET) (See p8)

Connect the camera to the monitor, then press the SET button for about 3 seconds to display the on-screen menu.

5RS-485 control push-lock terminals (RS485, A, B, G)

Use a cable thicker than AWG22.

2

1

ZOOM

COM IN

FOCUS

ALARM OUT

VIDEO OUT

POWER

AC24V

RS485

Control5

A B G

GND

A: Twisted-pair cable terminal

G: Ground terminal

B: Twisted-pair cable terminal

 

6

DC12V

 

 

 

 

CLASS 2 WIRING

 

 

 

 

 

 

1 Video output connector (VIDEO OUT: BNC type)

Connect this connector to a device such as a time lapse VCR or monitor with a VIDEO IN connector.

2Power indicator (POWER)

Comes on when the power to the camera is on.

Note: After connecting the power supply the POWER indicator will blink for 5 seconds. During this time no adjustments using the menus or any other operation are possible.

3 Cursor button (See p8)

j: Press this button to move the cursor up.

c: Press this button to move the cursor to the right, or to turn the settings ON/OFF etc.

d: Press this button to move the cursor to the left, or to turn the settings ON/OFF etc.

l: Press this button to move the cursor down.

6 24 V AC or 12 V DC input terminals (AC 24 V, DC 12 V,

GND)

Lens cap

The cap is installed to protect the lens section. Remove the cap when using the camera.