Section 4. Programming Reference

Sensor Type

Command Structure <ESC>IGa

 

a

=

0

Reflective (Eye Mark) sensor

 

 

 

1

See-thru (transmissive) sensor

 

 

 

2

Sensor not used

 

Example:

 

See above

 

Placement:

Separate data stream sent to printer

 

Default:

 

Default value set by <ESC>PG command

Command Function

To select the label sensing method for a job.

Input to Printer

<ESC>A

 

 

 

<ESC>IG1

 

 

 

<ESC>Z

 

 

Printer Output

There is no printer output as a result of this command

Special Notes

1.

When power is cycled, the value set by this command is lost and

replaced by the default value stored in the EEPROM.

2. To change the value stored in the EEPROM, use the <ESC>PG Printer Setting command or use the Printer Setting Utility program contained on the CDROM shipped with the printer.

SATO CT Series Printers

9001069A

Page 4-89

Page 133
Image 133
SATO CT400, CT410 manual Sensor Type, Command Structure ESCIGa