SATO CT400, CT410 Counter Status SOH + ME, Sensor Status SOH + SG, Byte Value Description Number

Models: CT410 CT400

1 199
Download 199 pages 30.79 Kb
Page 147
Image 147

Section 5. Interface Specifications

Counter Status (SOH + ME)

Upon Receipt of an SOH (hexadecimal 01) followed immediately by an ME (hexadecimal 4D45) causes the printer to return a 28 byte Head Counter Status Word bounded by an STX-ETXpair that reports the current status of the printer life counters.

BYTE

VALUE

DESCRIPTION

NUMBER

 

 

 

 

 

 

 

 

1-8

Binary

Current Life Counter in dots

 

 

 

9-12

Binary

1st (Current) Head Counter in dots

 

 

 

13-16

Binary

2nd (Previous) Head Counter in dots

 

 

 

17-20

Binary

3rd Head Counter in dots

 

 

 

21-24

Binary

Cutrrent Cut Counter in dots

 

 

 

25-28

Binary

Current Dispense Counter in dots

 

 

 

 

 

 

Sensor Status (SOH + SG)

Upon Receipt of an SOH (hexadecimal 01) followed immediately by an SG (hexadecimal 5347)causes the printer to return a 4 byte Sensor Status Word bounded by an STX-ETXpair that reports the values of the printer counters.

BYTE

VALUE

DESCRIPTION

NUMBER

 

 

 

 

 

 

 

 

1

Binary

See-Thru Sensor Level (0 to 255)

 

 

 

2

Binary

Transmissive Sensor Level (0 to 255)

 

 

 

3

00H

Out of Paper

 

01H

Paper Present

 

 

 

4

00H

Head Open

 

01H

Head Closed

 

 

 

 

 

 

SATO CT Series Printers

9001069A

Page 5-13

Page 147
Image 147