Section 4. Programming Reference

Printer Output

Special Notes

1.

The value specified for Print Quantity should be equal to the

 

 

number of different sequential values desired multiplied by the

 

 

number of repeats specified.

 

Example:

 

 

To print 2 sets each of the numbers 1001-1025 on separate

 

 

labels, we need 50 total labels. The commands would be as

 

 

follows:

 

 

<ESC>A

 

 

<ESC>H0100<ESC>V0100<ESC>F0002+001<ESC>XM1001

 

 

<ESC>Q50

 

 

<ESC>Z

 

2.

It is necessary to specify the print position for each sequential field

 

 

on a label.

 

3.

Up to eight different sequential fields can be specified per label.

 

4.

This command ignores alpha characters in the sequential number

 

 

field for decimal counting after the last hexidecimal (F) character.

 

5.

This command can not be used with the following commands:

 

 

Copy Image

 

 

Reverse Image

 

 

Line Feed

 

6.

The “a” field can be omitted. If it is omitted, the sequential

 

 

numbering will be a decimal count.

SATO CT Series Printers

9001069A

Page 4-69

Page 113
Image 113
SATO CT400, CT410 manual Value specified for Print Quantity should be equal to