Schneider Electric DS301 manual State machine drivectrl

Models: DS301

1 102
Download 102 pages 21.06 Kb
Page 36
Image 36

3 Basics

IL•1F CANopen DS301

State machine – drivectrl

The state machine is controlled via PDO4 or the SDO object drivectrl, 28:1, in both cases via bits Bits 0 ... 4.

In PDO mode, a change form 0 to 1 triggers the corresponding function.

In the case of access via SDO, a write access with a set bit value is suf- ficient, i.e. a change of edge is not required.

Controlling the state machine

PDO4Bits 0 ... 4

SDO object drivectrl, 28:1Bits 0 ... 4

Bit 0: Power stage Disable

Triggered when 0 changes to 1

Triggered at write access if bit value = 1

 

 

 

Bit 1: Power stage Enable

 

 

 

 

 

Bit 2: Quickstop

 

 

 

 

 

Bit 3: Fault Reset

 

 

 

 

 

Bit 4: Quickstop Release

 

 

 

 

 

The value "0" is a special case: If during transmission all bits 0 ... 7 are "zero", the product interprets this as "Disable" command and disables the power stage. This applies to both PDO and SDO access.

Handling of errors If requests for controlling the state machine cannot be executed by the product, the product ignores such request. There is no error response.

0198441113586, V2.01, 11.2008

36