Schneider Electric DS301 manual Subindex 03 h, inhibit time TPDO4 Meaning

Models: DS301

1 102
Download 102 pages 21.06 Kb
Page 90
Image 90

8 Object directory

IL•1F CANopen DS301

Subindex

03h, inhibit time T_PDO4

Meaning

Delay time for repeated transmission (in [100μsec]). The

 

value is rounded down to milliseconds as an integer

 

value.

Access

read-write

PDO mapping

Value range

0...65535

Default value

0

Can be saved

 

 

 

 

Subindex

04h, reserved T_PDO4

Meaning

Reserved (for compatibility purposes only)

Access

read-write

PDO mapping

Value range

Default value

Can be saved

 

 

 

 

Subindex

05h, event timer T_PDO4

Meaning

Time setting for event triggering

Access

read-write

PDO mapping

Value range

Default value

0

Can be saved

 

 

The meaning of the bit states and subindex values is described with the object receive PDO4 communication parameter (1403h).

Settings R_PDO4 is transmitted asynchronously and in an event-driven way.

The byte assignment of T_PDO4 is specified via PDO mapping with the object transmit PDO4 mapping (1A03h) and cannot be modified. The assignment is described in 3.4.2.3 "Transmit PDO T_PDO4 (prod- uct to master)".

The COB ID of the object can be changed in the NMT state "Pre-Oper- ational".

1A03h Transmit PDO4 mapping

The object specifies the objects mapped in T_PDO4 and transmitted with the PDO. When the object is read, subindex 00h, the number of mapped objects is read.

Object description

Index

1A03h

Object name

transmit PDO4 mapping

Object code

RECORD

Data type

PDO Mapping

 

 

0198441113586, V2.01, 11.2008

90

Fieldbus interface

Page 90
Image 90
Schneider Electric DS301 manual Subindex 03 h, inhibit time TPDO4 Meaning