IL•1F CANopen DS301

3 Basics

Operating modes – modeCtrl

In PDO mode, the operating modes are controlled via object modeCtrl. The master must enter the following values to activate an operating mode or to change reference values:

Reference values in fields "Ref16" and "Ref32"

Select operating mode with modeCtrl, Bits 0 ... 2 (MODE)

Select action for this operating mode with modeCtrl, bits 4 ... 6 (ACTION)

Toggle modeCtrl, bit 7 (MT)

The following table shows the possible operating modes and the corre- sponding reference values:

Mode bits

 

Action

modeCtrl

Description

Corre-

Reference value Ref16

Reference

0... 2

 

bits 4 ...

1). Bits 0

 

sponds to

 

value Ref32

 

 

6

... 6

 

object 2)

 

 

1

(JOG)

0

01h

Jog

41:3

Start (as object 41:1)

-

 

 

 

 

 

 

 

 

 

2

(REF)

0

02h

Position setting

40:3

-

Position for posi-

 

 

 

 

 

 

 

 

tion setting

 

 

 

 

 

 

 

 

 

 

 

1

12h

Reference movement

40:1

Type (as object 40:1)

-

 

 

 

 

 

 

 

 

3

(PTP)

0

03h

Absolute positioning

35:1

Reference speed

Reference posi-

 

 

 

 

 

 

 

 

tion

 

 

 

 

 

 

 

 

 

 

 

1

13h

Relative positioning

35:3

Reference speed

Reference posi-

 

 

 

 

 

 

 

 

tion

 

 

 

 

 

 

 

 

 

 

 

2

23h

Continue positioning

35:4

Reference speed

-

 

 

 

 

 

 

 

 

4

(VEL)

0

04h

Profile Velocity

36:1

Reference speed

-

 

 

 

 

 

 

 

 

 

1)Column corresponds to the value to be entered in byte modeCtrl, but without ModeToggle (bit 7)

2)Column shows Index:Subindex (decimal) of the corressponding operating mode objects modes which are described in more detail in the device documentation.

0198441113586, V2.01, 11.2008