Schneider Electric DS301 manual PDO4 mapping 1603h

Models: DS301

1 102
Download 102 pages 21.06 Kb
Page 92
Image 92

8 Object directory

IL•1F CANopen DS301

Subindex

03h, 3rd mapped object T_PDO4

Meaning

Third object for the mapping in T_PDO4

Access

read-only

PDO mapping

Value range

Default value

0x301E0708

Can be saved

 

 

 

 

Subindex

04h, 4th mapped object T_PDO4

Meaning

Fourth object for the mapping in T_PDO4

Access

read-only

PDO mapping

Value range

Default value

0x301E0820

Can be saved

 

 

The meaning of the bit states is described with the object receive

PDO4 mapping (1603h).

Settings The PDO assignment for T_PDO4 cannot be modified. The assigne- ment is described in 3.4.2.3 "Transmit PDO T_PDO4 (product to mas- ter)".

0198441113586, V2.01, 11.2008

92

Fieldbus interface

Page 92
Image 92
Schneider Electric DS301 manual PDO4 mapping 1603h