7 Diagnostics and troubleshooting

7.3CANopen error messages

CANopen error messages are signaled in the form of EMCY messages. They are evaluated via the objects Error register (1001h) and Error code (603Fh). For information on the object EMCY see chapter 3.4.2.5 "Emergency service".

CANopen signals errors that occur during data exchange via SDO with the special SDO error message ABORT.

7.3.1Error register

The object Error register(1001h) indicates the error state of a de- vice in bit-coded form. The exact cause of error must be determined with the error code table. Bit 0 is set as soon as an error occurs.

Bit

Message

Meaning

0

Generic error

An error has occurred

 

 

 

1

-

reserved

 

 

 

2

-

reserved

 

 

 

3

-

reserved

 

 

 

4

Communication

Network communication error

 

 

 

5

Device profile-specific

Error in execution as per device profile

 

 

 

6

-

reserved

 

 

 

7

Manufacturer-specific

Vendor-specific error message

 

 

 

7.3.2Error code table

The error code is evaluated with the object error code (603Fh), an object of the DSP402 device profile, and output as a four-digit hexadec- imal value. The error code indicates the cause of the last interruption of movement. See the Troubleshooting chapter of the product manual for the meaning of the error code.

0198441113586, V2.01, 11.2008

Fieldbus interface

77

Page 77
Image 77