IL•1F CANopen DS301

3 Basics

0198441113586, V2.01, 11.2008

COB IDs of the communication The following table shows the COB IDs of all communication objects objects with the factory settings. The column "Index of object parameters"

shows the index of special objects with which the settings of the com- munication objects can be read or modified via an SDO.

Communication object

Function

Node address,

 

COB ID decimal (hexadecimal)

Index of object

 

code

node ID [1...127]

 

 

 

parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

NMT Start/Stop Service

0 0 0 0

0

0

0

0

0

0

 

0

0 (0h)

 

-

SYNC object

0 0 0 1

0

0

0

0

0

0

 

0

128

(80h)

1005h....1007h

EMCY object

0 0 0 1

x x

x x

x x x

128

(80h) + node ID

1014h, 1015h

T_PDO1 1)

0 0 1 1

x x

x x

x x x

384

(180h) + node ID

1800h

R_PDO1 1)

0 1 0 0

x x

x x

x x x

512

(200h) + node ID

1400h

T_PDO2 1)

0 1 0 1

x x

x x

x x x

640

(280h) + node ID

1801h

R_PDO2 1)

0 1 1 0

x x

x x

x x x

768

(300h) + node ID

1401h

T_PDO3 1)

0 1 1 1

x x

x x

x x x

896

(380h) + node ID

1802h

R_PDO3 1)

1 0 0 0

x x

x x

x x x

1024

(400h) + node ID

1402h

T_PDO4

1 0 0 1

x x

x x

x x x

1152

(480h) + node ID

1803h

R_PDO4

1 0 1 0

x x

x x

x x x

1280

(500h) + node ID

1403h

T_SDO

1 0 1 1

x x

x x

x x x

1408

(580h) + node ID

-

R_SDO

1 1 0 0

x x

x x

x x x

1536

(600h) + node ID

-

NMT error control

1 1 1 0

x x

x x

x x x

1792

(700h) + node ID

 

LMT Services 1)

1 1 1 1

1

1

0 0

1 0

x

2020

(7E4h), 2021 (7E5h)

 

NMT Identify Service 1)

1 1 1 1

1

1

0 0

1 1

0

2022

(7E6h)

 

DBT Services 1)

1 1 1 1

1

1

0 0

x x x

2023

(7E7h), 2024 (7F8h)

 

NMT Services 1)

1 1 1 1

1

1

0 1

0 0

x

2025

(7E9h), 2026 (7EAh)

 

1) Not supported by the device

Table 3.4 COB IDs of all communication objects

COB IDs of PDOs can be changed as required. The assignment pattern for COB IDs only specifies a basic setting.

Function code The function code classifies the communication objects. Since the bits of the function code in the COB ID are more significant, the function code simultaneously controls the transmission priorities: Objects with a lower function code are transmitted with higher priority. For example, an object with function code "1" is transmitted prior to an object with func- tion code "3" in the case of simultaneous bus access.

Node address Every network device is configured before it is operated on the network. The device is assigned a 7 bit node address (node ID) between 1 (01h) and 127 (7Fh). The device address "0" is reserved for "broadcast" trans- missions which are used to send messages to all devices simultane- ously.

Fieldbus interface