IL•1F CANopen DS301

6 Operation

6.3Changing operating states with PDO4

The product operates in different operating states. The individual oper- ating states are numbered from 1 to 9 . The operating states and the transition conditions are described in more detail in the product manual, chapters "Basics" and "Operation".

Operating

Name

Power

Description

state

 

stage

 

 

 

 

 

4

Ready To Switch On

off

Passive operating state,

 

 

 

motor without current

 

 

 

 

6

Operation Enable

on

Active operating state, current

 

 

 

available to motor

 

 

 

 

7

Quick Stop active

on

Fault state, power stage

 

 

 

remains enabled

 

 

 

 

9

Fault

off

Fault state, power stage is

 

 

 

disabled

 

 

 

 

Table 6.1 Important operating states

Requests for switching operating states are transmitted to the product in R_PDO4 in the field drivectrl. The product signals the current oper- ating state back to the master in T_PDO4, field driveStat.

Table 6.2 shows the bit assignment of the field drivectrl in the object

R_PDO4:

Bit no.

Value

Meaning

0

01h

Disable

1

02h

Enable

2

04h

Quick Stop

3

08h

Fault Reset

4

10h

Quick Stop release

Table 6.2 R_PDO4, drivectrl, bit assignment

0198441113586, V2.01, 11.2008

Fieldbus interface

63

Page 63
Image 63