10 - 2 REPLACING THE SWITCH
In case
1Remove
2Disconnect the wiring connected to the Microswitch.
3Take out 2 screws to replace the Microswitch.
4Adjust Microswitch's actuator to an angular position so as not to touch the Switch when operating the Shift Lever.
5Fasten 2 screws to secure the Microswitch.
SCREW (2)
M2.3 X 10,w/flat & spring washers
MICROSWITCH
PHOTO 10. 2 a
6Check to ensure that the Switch goes ON and OFF in consistency with the operation.
SCREW (2)
M2.3 X 10,w/flat & spring washers
MICROSWITCH
PHOTO 10. 2 b
www.seuservice.com38