18.GAME BOARD
In order to prevent electric shock and short circuit hazards, be sure to turn power off before performing work.
Be careful so as not to damage wirings. Damaged wiring can cause fire, electric shock and short circuit hazards.
Do not expose the Game BD, etc. without a good reason. Failure to observe this can cause electric shock or malfunctioning.
STOP
IMPORTANT!
The electronic parts on the IC Board could be damaged due to human body's static electricity. Before performing IC Board related work, be sure to discharge physically accumulated statics by touching grounded metallic surfaces, etc.
Put the Game Board in the Carton Box (an accessory) together with the Shield Case when requesting for the replacement or repair. Transporting the Game Board in an undesignated status for replacement/repair is unacceptable.
18 - 1 TAKING OUT THE BOARD
1Turn power off.
2Take out the 2 truss screws, unlock and remove the Back Door Lower.
3Disconnect all of the Connectors connected to ASSY MAIN BOARD DX.
4Remove the 2 Wing Bolts and take out ASSY MAIN BD DX with the Shield Case as is mounted.
WING BOLT(2)
M4 X 25,flat washer used.
TRUSS SCREW(2)
M4 X 30,flat washer used.
FIG. 18. 1 a
71www.seuservice.com