Setting up the SDC 8000 system
1 | 2 | 3 | 4 |
1 | Load |
2 | Vac |
3
4
Connect the black RJ 45 plug of the system cable to the DATA OUT
socket | of the central unit. |
Connect the grey RJ 45 plug of the system cable to the DIGITAL BUS IN socket of the analog output unit.
Daisy-chaining SDC 8000 AO analog output units
To
Connect the DIGITAL BUS OUT socket of the first SDC 8000 AO to the DIGITAL BUS IN socket of the second SDC 8000 AO, and so on.
Note!
You can connect up to four
Connecting external equipment to the SDC 8000 AO’s phoenix connector
The SDC 8000 AO is fitted with a
The phoenix connector is numbered from left to right as shown in the illustration on the left.
If you switch AC loads such as e.g. an electronic relay, the contacts 1 and 3 will be opened or
Maximum load current (continuous) = 1 A
Maximum load voltage = 60 V
1
2
3
4
+Vdc
- Vdc
If you connect DC sources such as e.g. a relay coil, make sure that the following limitations are not exceeded!
Maximum load current (continuous) = 1.8 A
Maximum load voltage = 60 V
52