Configuring the SDC 8000 system
Initialize Units
1 Full Init
Press Mic to confirm
BOOTH | DESK |
01 | 01 |
Full Init
Press ENTER to save
|
|
| 01 | ENG |
|
|
| 02 | ARA |
00 | 00 | 00 | 00 |
|
FLO | FLO | FLO | FLO |
|
|
|
|
|
|
Initialize Units
1 Full Init
Once you have configured the number of interpreter booth (see “Setting the max. number of interpreter booths/languages” on page 86) and the number of interpreter consoles per booth (see “Setting the max. number of interpreter consoles per booth” on page 86), you have to initialize all interpreter consoles on the central unit as follows:
From the central unit’s operating menu, choose “Interpretation”, “Initialize Units” and “Full Init” one after the other.
The red signal light rings on all interpreter consoles start flashing and the displays of the interpreter consoles show “01” for both the booth and the desk number.
1.If all of the interpreter consoles which were configured via the central unit are connected, you can
Start initializing the interpreter consoles by pressing the MICRO key of interpreter console 1 in booth 1.
The red signal light ring of the interpreter console stops flashing. The booth and desk numbers of all subsequent interpreter consoles are automatically increased according to the preset number of booths and the preset number of interpreter consoles per booth.
Continue by pressing the MICRO key of interpreter console 2 in booth 1, and so on.
If all booth and desk numbers are assigned correctly, press the ENTER key on the central unit to save this configuration.
The displays of the interpreter consoles show the languages assigned to the
The interpreter consoles are now ready for operation.
2.Alternatively, you can assign the booth and desk number of an interpreter console individually (see “Manually assigning an interpreter console an individual booth number” on page 90 and “Manually assigning an interpreter console an individual desk number (interpreter console number)” on page 91).
Manually assigning an interpreter console an individual booth number
To manually assign an interpreter console an individual booth number (BOOTH):
From the central unit’s operating menu, choose “Interpretation”, “Initialize Units” and “Full Init” one after the other.
90