Sharp CD2200M x2/x3, Air Filter Cycle, ProcedureDisplay, To set magnetron failure options

Models: CD2200M CD1800M R-CD1200M

1 92
Download 92 pages 52.18 Kb
Page 17
Image 17
Air Filter Cycle

Air Filter Cycle

Air Filter Cycle can be changed from the factory setting of 100 hours to 001-999 hours

* Suppose you want to set the cycle to 250 hours.

ProcedureDisplay

CUSTOM

8

2

HELP x 2

10.Multiplication Factor for Double/Triple Quantity The multiplication factors of the double and triple quantities for memory cooking are preset to 1.80 and 2.60. You can check or change the multiplication factors.

*Suppose you want to know the multiplication factor for double quantity with memory 1, and change it to 2.00 in any Memory Input Method.

1 Press the CUSTOM HELP

After about 1 sec.

pad twice within 2 seconds

 

 

 

 

and enter 8, 2.

 

 

 

 

 

 

 

 

 

CHECK

 

 

 

 

 

SELECT

TIME

2 Press the SELECT TIME pad.

Procedure

CUSTOM

x2/x3

HELP x 2

1Press the CUSTOM HELP pad twice within 2 seconds and press the DOUBLE/TRIPLE QUANTITY pad.

Display

NO. CHECK

2 x2/x3To set magnetron failure options 5 Manual backgroundManual background 0

3Enter desired time.

(Ex : Enter 2, 5, 0 for 250 hours).

0

1

2 Enter memory number.

NO. CHECK

NO. CHECK

START

4 Press the START pad to save settings.

STOP

CLEAR

5Press the STOP/CLEAR pad to exit from the Custom Help Function.

9.Selecting Operation in case of Magnetron Failure

Your oven has 2 magnetrons. In case of single magnetron failure, the oven can be used until servicing by changing settings to allow operation under single magnetron only. However, check food carefully as additional cooking time will be needed when operating with a single magnetron.

CH91 : Yourovendoesnotworkwhenonemagnetron fails = Factory setting

CH92 : Your oven works even if one magnetron fails.

To set magnetron failure options

Press the CUSTOM HELP pad twice within 2 seconds then enter the numbers

9, 1 to stop operation when one magnetron fails 9, 2 to allow operation of one magnetron only

Press the START pad to save settings and the STOP/ CLEAR pad to exit from the Custom Help Function.

After about 1 sec.

CHECK

SELECT

TIME

3 Press the SELECT TIME pad.

2 Manual backgroundManual background 0 Manual backgroundManual background 0

4Enter desired multiplication. (Ex : Enter 2, 0, 0 for 2.00.)

START

NO. CHECK

5Press the START pad to save settings.

STOP

CLEAR

6Press the STOP/CLEAR pad to exit from the Custom Help Function.

EN-16

Page 17
Image 17
Sharp CD2200M, R-CD1200M, CD1800M x2/x3, Air Filter Cycle, ProcedureDisplay, To set magnetron failure options