Administration

Multiline Appearance/Keyset

>mended. For operating the DLS, please refer to the DLS user’s guide. Alternatively, the web interface or the local menu can be used. Note that the creation of a new line key and the configuration of some parameters can not be accomplished by the pho- ne’s local menu.

Generally, it is advisable to restrict the user’s possibilities to modify line keys. This

can be achieved solely by the DLS. For further instructions, see the DLS Administra- tion Guide.For the configuration of line keys, the use of the DLS (Deployment Service) is recom-

The Realm, a protection domain used for authenticated access to the SIP server, works as a name space. Any combination of user id and password is meaningful only within the realm it is assigned to. The other parameters necessary for authenticated access are User Identifier and Password. For all three parameters, there must be corresponding entries on the SIP server.

The Shared type parameter determines whether the line is a shared line, i. e. shared with other endpoints, or a private line, i .e. available exclusively for this endpoint. A line that is configured as primary line on one phone can be configured as secondary line on other phones.

When Allow in Overview is set to "Yes", the line will be visible in the line overview on the phone’s display.

Data required

Key label <n>: Set the label of the line key with the key number <n>.

Default: "Line".

Primary line: Determines whether the line is the primary line.

Value range: "Yes", "No".

Default: "No".

Ring on/off: Determines whether the line rings on an incoming call.

Value range: "On", "Off".

Default: "On".

Ring delay: Time interval in seconds after which the line starts ringing on an incoming call.

Default: 0.

Selection order: Priority assigned to the line for the selection of an outgoing line.

Default: 0.

Address: Address/phone number which has a corresponding entry on the SIP server/ registrar.

Realm: Domain wherein user id and password are valid.

User Identifier: User name for authentication with the SIP server.

Password: Password for authentication with the SIP server.

A31003-O1010-M100-9-76A9, 05/05/2008