9300 Series User’s Guide Diagnostic Menu
Chapter 2 - Using The Front Panel Page 37
The Ethernet Connection diagnostic screen displays text similar to what you see
in the table below - each label appears with a value next to it. The table explains
the meaning of each possible value.
I/O Diagnostics
The I/O diagnostics mode verifies the operation of the digital inputs/outputs you
may have connected to the device and, if you ordered the analog I/O option, allows
you to monitor the Analog Input or Analog Output ports on your meter. analog
inputs/outputs. The following diagnostic screens are available:
Digital Ins – This screen displays the four digital input values as seen at the low
level.
Digital Outs – This screen displays the four digital input values as seen at the
low level.
Analog Ins – This screen displays the four analog inputs’s values as seen at each
Analog Input module’s output register.
Analog Outs – This screen displays the four analog outputs’s values as seen at
each Analog Output module’s output register.
Troubleshooting Diagnostics
There are three troubleshooting diagnostic screens available. They are as follows:
kiloWatts – This screen shows per-phase and total kiloWatts.
Volts – This screens shows line to neutral and average volts.
Power Factor – This screen shows signed per-phase and total power factor.
Date/Time Screen
For the 9330 and 9350 meters, this screen displays the time and date from the
device’s internal clock.
For the 9300 meter, this screen displays the time passed sent during a time sync.
The 9300 meter does not increment its internal clock while the meter is powered-
down.
Label Possible Values Description
# Power Ups see description Displays the number of times the Ethernet card has power
cycled
Connection N/A, ION,
Modbus
The type of Ethernet connection:
N/A indicates no connection
ION indicates ION over Ethernet
Modbus indicates either Modbus RTU over Ethernet or Modbus
TCP
# WEB Reqs see description Displays the number of received WEB Page requests
# MeterM@il see description Displays the number MeterM@ils sent