Chapter 3 — Hardware Setup

Contents

Switch SW 1

Function

Description

 

Details

 

 

 

 

Datalink

 

 

SW1-7 and 8

 

 

 

Options

Allows the User to

 

 

 

 

 

 

 

 

 

 

 

select the level of

 

8

 

 

7

 

 

 

 

 

 

Datalink support the

 

off

off

No Datalinks

 

 

1560-MBP unit will

 

off

on

Datalink A only

 

have when talking to

 

on

off

Datalink A&B only

 

the SCANport device.

 

on

on

Datalink A,B,C,D

 

Some devices do not

 

 

 

 

 

 

 

 

 

 

 

support Datalinks, in

 

 

 

 

 

 

 

 

 

 

 

which case the ‘No

 

 

 

 

 

 

 

 

 

 

 

Datalinks’ option must

 

 

 

 

 

 

 

 

 

 

 

be selected.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Host

If the Global Data

SW1-1 to 6

 

 

 

PLC

Control is Enabled

1

Address Bit 0 Value = 1

Address

(SW2-7 is set to 1)

2

Address Bit 1 Value = 2

(when Global

then the 1560-MBP

3 Address Bit 2

Value = 4

Data Control

must be told which

4 Address Bit 3

Value = 8

Enabled)

Host PLC Global

5 Address Bit 4

Value = 16

 

Database to get the

6 Address Bit 5

Value = 32

 

control values from.

Example Addresses = 1 to 64

 

 

 

To select the

6

 

5

4

3

2

1

Address

 

off

 

off

off

off

off

off

1

 

appropriate Host,

off

 

off

off

off

off

on

2

 

determine the Host’s

off

 

off

off

off

on

off

3

 

off

 

off

off

off

on

on

4

 

Modbus Plus address

 

 

off

 

off

off

on

off

off

5

 

and select that

off

 

off

off

on

off

on

6

 

address using the dip

off

 

off

off

on

on

off

7

 

off

 

off

off

on

on

on

8

 

switches SW1- 1 to 6.

off

 

off

on

off

off

off

9

 

 

off

 

off

on

off

off

on

10

 

 

off

 

off

on

off

on

off

11

 

 

off

 

off

on

off

on

on

12

 

 

off

 

off

on

on

off

off

13

 

 

off

 

off

on

on

off

on

14

 

 

off

 

off

on

on

on

off

15

 

 

off

 

off

on

on

on

on

16

 

 

off

 

on

off

off

off

off

17

 

 

off

 

on

off

off

off

on

18

 

 

off

 

on

off

off

on

off

19

 

 

off

 

on

off

off

on

on

20

 

 

off

 

on

off

on

off

off

21

 

 

off

 

on

off

on

off

on

22

 

 

off

 

on

off

on

on

off

23

 

 

off

 

on

off

on

on

on

24

 

 

off

 

on

on

off

off

off

25

 

 

off

 

on

on

off

off

on

26

 

 

off

 

on

on

off

on

off

27

 

 

 

 

 

 

 

 

 

 

 

 

11

Page 11
Image 11
SMC Networks 1560 user manual Switch SW